  1. Connecting rigid pvc conduit to flex pvc conduit - Electrician Talk

    Aug 19, 2016 · Looking for proper way to make a Rigid PVC connection to a Flex PVC conduit?

  2. PVC to non metallic liquid tight transition - Electrician Talk

    Jun 26, 2019 · This is pvc pipe from a gfci disconnect to a hot tub but I want to finish the last portion of conduit into the tub with non metallic liquid tight. What is the go to method for such transitions? I am …

  3. transitioning from one type of conduit to another - Electrician Talk

    Apr 19, 2018 · I ran some flex metal conduit through a short, difficult section of basement to rigid PVC in a garage, with adapters from one to the other. There was some discussion as to whether it was code …

  4. connecting rigid PVC to nonmetallic liquidtight???

    Oct 4, 2018 · I'm wanting to convert from rigid 1-1/4 PVC to flexible nonmetallic conduit, using a rigid pvc female adapter to a flex straight terminal (male) adapter. I believe this is compliant. I would be …

  5. Use of liquid-tight flexible conduit - Electrician Talk

    Feb 15, 2023 · 1) Liquid-tight flexible conduit shall be permitted where a flexible connection is required in dry, damp, or wet locations and where permitted by other Sections of this Code. Can liquid-tight …

  6. flexible nonmetallic conduit question - Electrician Talk

    Oct 6, 2007 · I hope this is the right forum for this question. I ran across a job last week where there is quite a bit of flexible nonmetallic conduit in use. It is "carflex" conduit but at every box connection the …

  7. schedule 80 PVC - Electrician Talk

    Aug 31, 2024 · Frost heave is a serious problem for damaging pvc stubs that exit the soil and attach to a building here. I would probably opt for schedule 80 with an expansion coupling and a loop of wire in …

  8. Smurf Tube - Electrician Talk

    Dec 7, 2008 · Is this smurf tube like coreline? gray or blueish plastic flexible pvc pipe, made by Ipex (the stuff we use anyways). If yes then I love it, and we use a LOT of it, I have personally put 140k feet of …

  9. Bending 2" pvc - Electrician Talk

    Apr 28, 2014 · For the first time I attempted to bend a 90 with 2" pvc but it kinked up like crazy after removing it from my hot box. I'll just use a premade 90 when I do the job I needed it for, but if you've …

  10. Sleeving UF in PVC - Electrician Talk

    Jul 22, 2013 · My calculations say that a 12-2 should fit in 1/2" PVC LB as well as 1/2" schd 40 PVC. Any objections to that? I know 3/4" would be easier to pull the UF thru, but I would like to use the …