  1. Dwelling kitchen receptacles required - 210.52 (A) (2) (1) and 210.52 ...

    Mar 8, 2022 · As a receptacle can be up to 5-1/2 feet above the floor and still serve the wall space, is there an issue? The countertop receptacles can serve the wall space. And since the countertop …

  2. NEC 210.52 (E) Outdoor outlets | Information by Electrical ...

    Aug 23, 2021 · The receptacle outlet shall not be located more than 6.5 feet above the balcony, deck, or porch walking surface. If there is a screened-in lanai (aluminum structure with insect screening) …

  3. Receptacle in a shallow box? | Information by Electrical Professionals ...

    Nov 23, 2020 · Quick question: Can a GFI receptacle be installed in a 1-1/4" deep box? Or perhaps a regular receptacle that is down stream of a GFI?

  4. Receptacle Termination & Wire Sizes | Information by Electrical ...

    May 2, 2007 · What is the largest size wire that can safely land on a receptacle termination? We normally use #12s everywhere, #10s for long distance runs but will #8s work? Is there some UL …

  5. 20A receptacle on a 15A circuit residential | Information by Electrical ...

    Jun 1, 2025 · To add: looking only at the receptacle on the right (below), note that the contacts on both sides can accommodate either a vertical or a horizontal blade. For a given grade of receptacle, the …

  6. Hallway receptacles | Information by Electrical Professionals for ...

    Feb 13, 2020 · I agree with Dennis in the 2008 NEC for hallways less than 10' no receptacle required, more than 10' one required. And it doesn't matter if one side of your hallway has doors and the other …

  7. Kitchen Counter Receptacle | Information by Electrical Professionals ...

    Jun 8, 2024 · I have a Kitchen Countertop and Work Surface according to 210.52(C) that is 24-inches wide but has a cabinet that comes right down onto the countertop thereby leaving only 9-inches of …

  8. What's considered "convenience receptacle"? | Information by Electrical ...

    Jul 19, 2012 · What does the NEC consider as a convenience receptacle? If there isn't a specific appliance, then this is a convenience receptacle? Is a TV connected to a receptacle considered a …

  9. 6' Rule or Article 210.52 (A) (1) Spacing? - Mike Holt's Forum

    Dec 14, 2009 · Aloha, Mike Holt Forum In the NEC 08'- Article 210.52 (A) (1) Spacing states; Receptacles shall be installed such that no point measured horizontally along the floor line in any …

  10. 2020 NEC Island outlet placement question. | Information by Electrical ...

    May 30, 2024 · 2020 Code Language: Article 100. Receptacle. A contact device installed at the outlet for the connection of an attachment plug, or for the direct connection of electrical utilization equipment …